دانلود مقاله Design and Analysis of Magnetizing Coil for Magnet

دانلود مقاله Design and Analysis of Magnetizing Coil for Magnetic Resonance Imaging Systems. Hollow Cylindrical Coil Design فایل ورد (word) دارای 7 صفحه می باشد و دارای تنظیمات در microsoft word می باشد و آماده پرینت یا چاپ است
فایل ورد دانلود مقاله Design and Analysis of Magnetizing Coil for Magnetic Resonance Imaging Systems. Hollow Cylindrical Coil Design فایل ورد (word) کاملا فرمت بندی و تنظیم شده در استاندارد دانشگاه و مراکز دولتی می باشد.
این پروژه توسط مرکز مرکز پروژه های دانشجویی آماده و تنظیم شده است
توجه : در صورت مشاهده بهم ریختگی احتمالی در متون زیر ،دلیل ان کپی کردن این مطالب از داخل فایل ورد می باشد و در فایل اصلی دانلود مقاله Design and Analysis of Magnetizing Coil for Magnetic Resonance Imaging Systems. Hollow Cylindrical Coil Design فایل ورد (word) ،به هیچ وجه بهم ریختگی وجود ندارد
بخشی از متن دانلود مقاله Design and Analysis of Magnetizing Coil for Magnetic Resonance Imaging Systems. Hollow Cylindrical Coil Design فایل ورد (word) :
سال انتشار: 1393
محل انتشار: بیست و نهمین کنفرانس بین المللی برق
تعداد صفحات: 7
نویسنده(ها):
Mohammadreza Shiravi Khoozani – Department of Electrical Engineering Tafresh University Tafresh, Iran
Homayoun Meshgin Kelk – Department of Electrical Engineering Tafresh University Tafresh, Iran
Abolfazl Shiravi Khoozani – Department of Medicine Tehran University of Medical Sciences Tehran, Iran
چکیده:
A typical medical Magnetic Resonance Imaging (MRI) contains a large electromagnet capable of creating a static magnetic field in the range of 0.5 Tesla (T) to 3.0 T with a uniformity across the tunnel of 0.5 parts per million (ppm). The central volume, in which patients are placed, is called the tunnel. The main purpose of this work is to design a thick solenoid coil for MRI scanner. Two key factors in this design are field homogeneity and minimum wired volume consumption. In terms of field homogeneity, I must apply multi constrains, one is considering of superconducting features; another is to apply discretizing and cancelling methods. Here, researches is focused on second key factor (namely optimum wired volume). The procedure which is proposed in this paper is simulated by MATLAB and MAXWELL 16.0 software which can be used in wide variety of solenoid coil design industry, in the range from micro to macro dimension. For example in macro rang, there is an electrical machine in electrical power systems that named superconductor magnetic energy storage (SMES), this generates strength field (i.e. a 5 Tesla). And in micro rang we can mention miniature medical diagnostic coils.

کلمات کلیدی :
» نظر